SCIENCE CHINA Technological Sciences, Volume 59 , Issue 10 : 1463-1474(2016) https://doi.org/10.1007/s11431-016-6087-1

Progress of entransy analysis on the air-conditioning system in buildings

More info
  • ReceivedFeb 26, 2016
  • AcceptedApr 29, 2016
  • PublishedAug 11, 2016

Abstract

It is of great importance to improve the energy performance of the air-conditioning system for building energy conversation. Entransy provides a novel perspective to investigate the losses existing in the air-conditioning system. The progress of entransy analysis in the air-conditioning system is comprehensively investigated in the present study. Firstly missions and characteristics of the air-conditioning system are analyzed with emphasis on heat or mass transfer process. It is found that reducing the temperature difference, i.e. reducing the entransy dissipation helps to improve the performance. Entransy dissipations and thermal resistances of typical transfer processes in the air-conditioning system are presented. Characteristics of sensible heat transfer process and coupled heat and mass transfer processes are researched in terms of entransy dissipation analysis. Reasons leading to entransy dissipation are also clarified with the help of unmatched coefficient ξ. Principles for reducing the entransy dissipation and constructing a high temperature cooling system are summarized on the basis of case studies in typical handling processes. It’s recommended that reducing mixing process, improving match properties are main approaches to reduce the entransy dissipation. The present analysis is beneficial to casting light on the essence of the air-conditioning system and proposing novel approaches for performance optimization.


Acknowledgment

This work was supported by National Natural Science Foundation of China (Grant Nos. 51422808 & 51521005), the National Science & Technology Pillar Program during the 12th Five-year Plan Period (Grant No. 2014BAJ02B01), and the China Postdoctoral Science Foundation (Grant No. 2015M570107).


References

[1] Building Energy Research Center of Tsinghua University . 2015 Annual Report on China Building Energy Efficiency. Beijing: China Architecture & Building Press. 2015, : 2-10 Google Scholar

[2] Pérez-Lombard L, Ortiz J, Pout C. A review on buildings energy consumption information. Energ Buildings, 2008, 40: 394-398 CrossRef Google Scholar

[3] Chua K J, Chou S K, Yang W M, et al. Achieving better energy-efficient air conditioning–A review of technologies and strategies. Appl Energ, 2013, 104: 87-104 CrossRef Google Scholar

[4] Yu F W, Chan K T. Improved energy performance of air cooled centrifugal chillers with variable chilled water flow. Energ Convers Manage, 2008, 49: 1595-1611 CrossRef Google Scholar

[5] Saidur R, Hasanuzzaman M, Mahlia T M I, et al. Chillers energy consumption, energy savings and emission analysis in an institutional buildings. Energy, 2011, 36: 5233-5238 CrossRef Google Scholar

[6] Perez-Lombard L, Ortiz J, Maestre I R. The map of energy flow in HVAC systems. Appl Energ, 2011, 88: 5020-5031 CrossRef Google Scholar

[7] Xiao F, Wang S W. Progress and methodologies of lifecycle commissioning of HVAC systems to enhance building sustainability. Renew Sust Energ Rev, 2009, 13: 1144-1149 CrossRef Google Scholar

[8] Yadav Y K. Vapour-compression and liquid-desiccant hybrid solar space conditioning system for energy conservation. Renew Energ, 1995, 6: 719-723 CrossRef Google Scholar

[9] Kusiak A, Xu G L, Tang F. Optimization of an HVAC system with a strength multi-objective particle-swarm algorithm. Energy, 2011, 36: 5935-5943 CrossRef Google Scholar

[10] Wang B X. Engineering Thermodynamics. Beijing: Higher Education Press. 2011, : 65-69 Google Scholar

[11] Shukuya M. Exergy concept and its application to the built environment. Build Environ, 2009, 44: 1545-1550 CrossRef Google Scholar

[12] Hurdogan E, Buyukalaca O, Hepbasli A. Exergetic modeling and experimental performance assessment of a novel desiccant cooling system. Energ Buildings, 2011, 43: 1489-1498 CrossRef Google Scholar

[13] Jain N, Alleyne A. Exergy-based optimal control of a vapor compression system. Energ Convers Manage, 2015, 92: 353--365 Google Scholar

[14] Gong S Y, Boulama K G. Advanced exergy analysis of an absorption cooling machine: Effects of the difference between the condensation and absorption temperatures. Int J Refrig, 2015, 59: 224-234 CrossRef Google Scholar

[15] Yucer C T, Hepbasli A. Thermodynamic analysis of a building using exergy analysis method. Energ Buildings, 2011, 43: 536-542 CrossRef Google Scholar

[16] Wei Z T, Zmeureanu R. Exergy analysis of variable air volume systems for an office building. Energ Convers Manage, 2009, 50: 387-392 CrossRef Google Scholar

[17] Manjunath K, Kaushik S C. Second law thermodynamic study of heat exchangers: A review. Renew Sust Energ Rev, 2014, 40: 348-374 CrossRef Google Scholar

[18] IEA-EBC Annex 37 . Guidebook to IEA ECBCS Annex 37-Low Exergy Systems for Heating and Cooling of Buildings. Finland: VTT Technical Research Centre of Finland. 2004, : 8-12 Google Scholar

[19] Schmidt D. Low exergy systems for high-performance buildings and communities. Energ Buildings, 2009, 331–336. Google Scholar

[20] Fan B, Jin X Q, Fang X, et al. The method of evaluating operation performance of HVAC system based on exergy analysis. Energ Buildings, 2014, 77: 332-342 CrossRef Google Scholar

[21] Sakulpipatsin P, Itard L C M, Van der Kooi H J. An exergy application for analysis of buildings and HVAC systems. Energ Buildings, 2009, 41: 90-99 Google Scholar

[22] Li R L, Ooka R, Shukuya M. Theoretical analysis on ground source heat pump and air source heat pump systems by the concepts of cool and warm exergy. Energ Buildings, 2014, 75: 447-455 CrossRef Google Scholar

[23] Guo Z Y, Zhu H Y, Liang X G. Entransy—A physical quantity describing heat transfer ability. Int J Heat Mass Tran, 2007, 50: 2545-2556 CrossRef Google Scholar

[24] Xia S J, Chen L G, Sun F R. Optimal paths for minimizing entransy dissipation during heat transfer processes with generalized radiative heat transfer law. Appl Math Model, 2010, 34: 2242-2255 CrossRef Google Scholar

[25] Chen Q, Ren J X. Generalized thermal resistance for convective heat transfer and its relation to entransy dissipation. Chin Sci Bull, 2008, 53: 3753-3761 CrossRef Google Scholar

[26] Xia S J, Chen L G, Sun F R. Optimal paths for minimizing entransy dissipation during heat transfer processes with generalized radiative heat transfer law. Appl Math Model, 2010, 34: 2242-2255 CrossRef Google Scholar

[27] Cheng X T, Liang X G. Entransy flux of thermal radiation and its application to enclosures with opaque surfaces. Int J Heat Mass Tran, 2011, 54: 269-278 CrossRef Google Scholar

[28] Chen Q, Liang X G, Guo Z Y. Entransy theory for the optimization of heat transfer-A review and update. Int J Heat Mass Transfer, 2013, 63: 65-81 CrossRef Google Scholar

[29] Sun J, Yuan K, Yang L J, et al. Distribution optimization of circulating water in air-cooled heat exchangers for a typical indirect dry cooling system on the basis of entransy dissipation. Sci China Tech Sci, 2015, 58: 617-629 CrossRef Google Scholar

[30] Wang W H, Cheng X T, Liang X G. Entransy dissipation, entransy-dissipation-based thermal resistance and optimization of one-stream hybrid thermal network. Sci China Tech Sci, 2013, 56: 529-536 CrossRef Google Scholar

[31] Wang W H, Cheng X T, Liang X G. T-Q diagram analyses and entransy optimization of the organic flash cycle (OFC). Sci China Tech Sci, 2015, 58: 630-637 CrossRef Google Scholar

[32] Cheng X T, Liang X G. T-q diagram of heat transfer and heat-work conversion. Int Commun Heat Mass Transfer, 2014, 53: 9-13 CrossRef Google Scholar

[33] Yang W W, Cao X Q, Zhou F, et al. Performance analysis of waste heat recovery methods by T-Q diagram. J Eng Thermophys, 2015, 36: 2107-2110 Google Scholar

[34] Qian X D, Li Z, Li Z X. Entransy and exergy analyses of airflow organization in data centers. Int J Heat Mass Tran, 2015, 81: 252-259 CrossRef Google Scholar

[35] Cheng X T, Liang X G. Analyses and optimizations of thermodynamic performance of an air conditioning system for room heating. Energy Buildings, 2013, 67: 387-391 CrossRef Google Scholar

[36] Cheng X T, Liang X G. Entransy and entropy analyses of heat pump systems. Chin Sci Bull, 2013, 58: 4696-4702 CrossRef Google Scholar

[37] Zhang L, Liu X H, Jiang Y. Application of entransy in the analysis of HVAC systems in buildings. Energy, 2013, 53: 332-342 CrossRef Google Scholar

[38] Çarpinlioğlu M Ö. A comment on the concept of entransy (versus exergy) for the performance assessment of a desiccant cooling system. Energ Buildings, 2015, 101: 163-167 CrossRef Google Scholar

[39] Zhang T, Liu X H, Zhang L, et al. Match properties of heat transfer and coupled heat and mass transfer processes in air-conditioning system. Energ Convers Manage, 2012, 59: 103-113 CrossRef Google Scholar

[40] Jiang Y, Liu X H, Zhang L, et al. High temperature cooling and low temperature heating in buildings of EBC Annex 59. In: Proceedings of the 6th International Building Physics Conference Torino Italy. 2015, Google Scholar

[41] Zhang L, Liu X H, Zhao K, et al. Entransy analysis and application of a novel indoor cooling system in a large space building. Int J Heat Mass Tran, 2015, 85: 228-238 CrossRef Google Scholar

[42] Zhang T, Liu X H, Jiang Y. Performance comparison of liquid desiccant air handling processes from the perspective of matched properties. Energ Convers Manage, 2013, 75: 51-60 CrossRef Google Scholar

[43] Zhang L, Liu X H, Jiang Y. Application of entransy in match property of liquid desiccant dehumidification. In: Proceedings of the 15th International Heat Transfer Conference Kyoto Japan. 2014, Google Scholar

[44] Liu X H, Xie X Y, Zhang T, et al. Thermal Principle of Indoor Built Environment. Beijing: China Architecture & Building Press. 2016, Google Scholar

[45] Li Z, Liu X H, Zhang L, et al. Analysis on the ideal energy efficiency of dehumidification process from buildings. Energ Buildings, 2010, 42: 2014-2020 CrossRef Google Scholar

[46] Liu X H, Jiang Y, Zhang T. Temperature and Humidity Independent Control (THIC) of Air-conditioning System. Berlin: Springer Press. 2013, : 200-212 Google Scholar

Copyright 2020 Science China Press Co., Ltd. 《中国科学》杂志社有限责任公司 版权所有

京ICP备17057255号       京公网安备11010102003388号