A novel approach framework based on statistics for reconstruction and heartrate estimation from PPG with heavy motion artifacts

More info
  • ReceivedMay 2, 2017
  • AcceptedJun 27, 2017
  • PublishedNov 13, 2017

Abstract

One of the most important applications of photoplethysmography (PPG) signal is heartrate (HR) estimation. For its applications in wearable devices, motion artifact (MA) may be the most serious challenge for randomness both in format and temporal distribution. This paper proposes an advanced time-frequency analysis framework based on empirical mode decomposition (EMD) to select specific time slices for signal reconstruction. This framework operates with a type of pre-processing called variance characterization series (VCS), EMD, singular value decomposition (SVD), and a precise and adaptive 2-D filtration reported first. This filtration is based on Harr wavelet transform (HWT) and 3rd order cumulant analysis, to make it have resolution in both the time domain and different components. The simulation results show that the proposed method gains 1.07 in absolute average error (AAE) and 1.87 in standard deviation (SD); AAEs 1st and 3rd quartiles are 0.12 and 1.41, respectively. This framework is tested by the PhysioBank MIMIC II waveform database.


Acknowledgment

This work was supported by National Natural Science Foundation of China (Grant Nos. 61634006, 61372060, 61335010, 61474107, 81300803), National Key Technologies R&D Program (Grant Nos. 2016YFB0401303, 2016YFB0402405), Basic Research Project of Shanghai Science and Technology Commission (Grant No. 16JC1400101), and Key Research Program of Frontier Science, Chinese Academy of Sciences (Grant No. QYZDY-SSW-JSC004).


References

[1] Selvaraj N, Jaryal A, Santhosh J, et al. Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography. J Med Eng Technol, 2008, 32: 479--484. Google Scholar

[2] Petersen C L, Chen T P, Ansermino J M, et al. Design and evaluation of a low-cost smartphone pulse oximeter. Sensors, 2013, 13: 16882--16893. Google Scholar

[3] Lee J, Jung W. Design the filter to reject motion artifact of pulse oximetry. Elsevier Comput Sci, 2003, 26: 241--249. Google Scholar

[4] Zhang Z, Pi Z, Liu B. TROIKA: a general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise. IEEE Trans Biomed Eng, 2015, 62: 522--531. Google Scholar

[5] Murthy N K L, Madhusudana P C, Suresha P, et al. Multiple spectral peak tracking for heart rate monitoring from photoplethysmography signal during intensive physical exercise. IEEE Signal Process Lett, 2015, 22: 2391--2395. Google Scholar

[6] Komaty A, Boudraa A O, Augier B, et al. EMD-based filtering using similarity measure between probability density functions of IMFs. IEEE Trans Instrum Meas, 2014, 63: 27--34. Google Scholar

[7] Yang G, Liu Y, Wang Y, et al. EMD interval thresholding denoising based on similarity measure to select relevant modes. Signal Process, 2015, 109: 95--109. Google Scholar

[8] Sung P, Syed Z, Guttag J. Quantifying morphology changes in time series data with skew. In: Proceedings of IEEE International Conference on Acoustics, Speech, and Signal Processing, ICASSP 2009, Taipei, 2009. 477--480. Google Scholar

[9] Wu Z, Huang N E. Ensemble empirical mode decomposition: a noise-assisted data analysis method. Adv Adapt Data Anal, 2009, 1: 1--41. Google Scholar

[10] Motin M A, Karmakar C, Palaniswami M. Ensemble Empirical Mode Decomposition with Principal Component Analysis: A Novel Approach for Extracting Respiratory Rate and Heart Rate from Photoplethysmographic Signal.. IEEE J Biomed Health Inform, 2017, : 1-1 CrossRef PubMed Google Scholar

[11] Pang B, Liu M, Zhang X, et al. Advanced EMD method using variance characterization for PPG with motion artifact. In: Proceedings of 2016 IEEE Biomedical Circuits and Systems Conference (BioCAS), Shanghai, 2016. 196--199. Google Scholar

[12] Huang N E, Shen Z, Long S R, et al. The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis. Proc Math Phys Eng Sci, 1998, 454: 903--995. Google Scholar

[13] Li P, Liu M, Zhang X, et al. A low-complexity ECG processing algorithm based on the Haar wavelet transform for portable health-care devices. Sci China Inf Sci, 2014, 57: 122303. Google Scholar

[14] Gao Y, Ge G, Sheng Z, et al. Analysis and solution to the mode mixing phenomenon in EMD. Congress Image Signal Process, 2008, 5: 223--227. Google Scholar

[15] Dimitrakopoulos R, Mustapha H, Gloaguen E. High-order statistics of spatial random fields: exploring spatial cumulants for modeling complex non-Gaussian and non-linear phenomena. Math Geosci, 2010, 42: 65--99. Google Scholar

[16] Donoho D L. De-noising by soft-thresholding. IEEE Trans Inf Theory, 1995, 41: 613--627. Google Scholar

[17] Li X, Zhang X, Li P, et al. An 8.12 μW wavelet denoising chip for PPG detection and portable heart rate monitoring in 0.18 $\mu$m CMOS. J Semicond, 2016, 37: 055006. Google Scholar

[18] Zhang Z. Photoplethysmography-based heart rate monitoring in physical activities via joint sparse spectrum reconstruction. IEEE Trans Biomed Eng, 2015, 62: 1902--1910. Google Scholar

Copyright 2019 Science China Press Co., Ltd. 《中国科学》杂志社有限责任公司 版权所有

京ICP备18024590号-1